ARTEL Extreme Pipetting Expedition Finds Humid Environment Ideal for Accurate and Precise Pipetting

ARTEL visits Olympic National Park for Mission 4 

New Orleans, LA (March 3, 2008) – The ARTEL Extreme Pipetting Expedition announces data showing that pipettes performed accurately and precisely in the humid Olympic National Park yet under-delivered significantly in a drier facility mimicking typical laboratory conditions.  For Mission 4, ARTEL studied the effect of humidity on pipetted volumes because regulatory standards recommend that pipette calibration take place in facilities with 60% relative humidity, while working laboratories commonly operate at 15-40% relative humidity. The data indicate that pipettes calibrated off-site are prone to under-deliver once returned to their usual environments

ARTEL is releasing the results from Mission 4 at PITTCON 2008 (booth #4303), March 3-6 at the Earnest N. Morial Center in New Orleans, LA.  Complete data can be found at www.artel-usa.com/extreme/results4.htm.

Calibrating Pipettes at Olympic National Park“In previous missions, ARTEL found significant liquid handling error when pipetting in extreme environments with factors such as low barometric pressure and dry heat.  Now, ARTEL found almost zero error in the extremely humid Olympic National Park,” says George Rodrigues, Ph.D., Senior Scientific Manager, ARTEL.  “Laboratory managers should consider if their facilities have conditions similar to those at Olympic National Park, with 74% relative humidity. If not, laboratory data integrity may be at risk.”

Pipettes performed well in the humid environment of Olympic National Park due to the low evaporation potential.  A function of both temperature and relative humidity, evaporation potential influences the rate of evaporation.  Greater evaporation occurs in warm environments than in cold environments when relative humidity is held constant, leading to temperature-dependent under-delivery.  The greater the evaporation potential, the more pronounced are pipetting inaccuracy and imprecision. 

Rialto Beach in Olympic National Park had a very low evaporation potential (4.5 mbar), with a temperature of 14 °C and relative humidity of 74%. Using the ARTEL PCS® Pipette Calibration System, ARTEL found that pipettes performed extremely well, with average inaccuracy of only -0.35% and an average imprecision ratio of 1.33.

Pipettes were also tested at Olympic Inn, with a temperature of 20 °C and relative humidity of 60% – an ideal regulatory specification for pipette calibration laboratories.  Pipettes performed well here, as expected, with average inaccuracy of -0.11% and an average imprecision ratio of 0.68. 

To quantify the difference in pipette performance in humid environments versus typical working laboratories, ARTEL pipetted in a laboratory with a temperature of 21 °C and relative humidity of 22%.  ARTEL found a statistically significant degradation in pipette performance here versus the 60% relative humidity environment, with average inaccuracy of -1.55% and an average imprecision ratio of 7.10.  These results call into question the performance of pipettes calibrated off-site, such as in a pipette calibration facility, and used in a drier working laboratory.  The data also support the need to calibrate pipettes in the environment in which they are used.

Olympic National Park was chosen as the location for Mission 4 because it is known for its lush, rainforest-like environment.  The Park is home to 266 glaciers, over 60 miles of Pacific coastline, and temperate conditions, with over 140 inches of rainfall each year. 

The Extreme Pipetting Expedition is a multi-phase, year-long scientific study illustrating the impact of laboratory environmental conditions on pipetting performance and data integrity.  Previous Expedition missions explored how pipetting data integrity is affected by barometric pressure, pipetting warm and cold liquids, and dry heat.  In the future, ARTEL plans to test pipette performance in actual working laboratories where the environment is believed to have an impact on data, and to offer laboratories concrete guidance on optimizing liquid handling operations. More information can be found at www.artel-usa.com/extreme.

About ARTEL
ARTEL is the worldwide leader in liquid handling quality assurance.  ARTEL manufactures the most accurate, precise and easy-to-use systems for ensuring data integrity in any process requiring liquid volume measurement. ARTEL systems, based on proprietary Ratiometric Photometry, conform to ISO 8655-7 and provide NIST-traceable results to ensure reproducible data and regulatory compliance. In addition, ARTEL provides liquid handling quality assurance support and consultation services including on-site pipetting technique training and certification for pipette users and laboratory managers, and Liquid Handler Performance Verification services for automated laboratories. Since 1982, ARTEL technology has been proven in daily use in thousands of laboratories including pharmaceutical, clinical, forensic, public health and environmental. Leading institutions such as Amgen, ARUP, Bristol-Myers Squibb, Celgene, Centers for Disease Control, DuPont, Eli Lilly, FBI, Genentech, Genomic Health, Mayo Clinic, Memorial Sloan-Kettering Cancer Center, Merck, Pfizer, Procter & Gamble and U.S. FDA depend on ARTEL technology to help them meet their objectives for quality and productivity. For more information, contact ARTEL at 25 Bradley Drive, Westbrook, ME 04092; Tel: 207-854-0860; Fax: 207-854-0867; Website: www.artel-usa.com.




News and Events

Corporate Headquarters


25 Bradley Drive
Westbrook, ME USA
04092-2013
Directions 

Tel:  207.854.0860
Fax: 207.854.0867
Toll-free (U.S. & Canada): 888.406.3463

Monday - Friday
8:00am – 5:00pm Eastern Time

E-mail:

Customer Service
Technical Support

 

Germany Office

Artel Germany
Business Development Europa
Im Grossacker 49, 79252 Stegen, Germany

Tel:   +49 (0)7661 982064
Fax:  +49 (0)7661 982065

Email:
sschork@artel-usa.com  

 

Outside U.S. & Canada:

International Distributors